Steam turbine R-11-1.5/0.3Ps (for the KhTGZ unit)
Steam turbine drive units with a power of up to 11,180 kW to drive feed pumps of power units of a state district power plant with a capacity of 300 MW. Turbo drives for pumps are also manufactured on civil vessels and for use in ammonia production lines.
Turbines operate at variable speeds over a wide range of loads with variable initial and final steam parameters.
Parameters of the turbine R-11-1.5/0.3Ps (for the KhTGZ unit)
rated power, kW | 10900 |
rated rotor speed, rpm | 4990 |
absolute fresh steam pressure, MPa | 1,45 |
fresh steam temperature, °C | 438 |
steam pressure behind the turbine, kPa | 0,27 |