Steam turbine TP-320
Steam turbine drive units with a power of up to 11,180 kW to drive feed pumps of power units of a state district power plant with a capacity of 300 MW. Turbo drives for pumps are also manufactured on civil vessels and for use in ammonia production lines.
Turbines operate at variable speeds over a wide range of loads with variable initial and final steam parameters.
Parameters of the TP-320 turbine
rated power, kW | 235 |
rated rotor speed, rpm | 9000 |
absolute fresh steam pressure, MPa | 1,37 |
fresh steam temperature, °C | 194 |
steam pressure behind the turbine, kPa | 0,12 |